Scott-T Transformer
Overview
A Scott-T transformer converts a three-phase supply into two single-phase outputs with a 90-degree phase displacement. It is used where the process requires two suitable single-phase loads rather than a conventional three-phase load. The source manual describes applications including glass melting and industrial furnaces. Input current balance depends on the relationship between the two loads. When their characteristics, power factors and loading are similar, the three-phase input can remain substantially balanced. Unequal loading changes that condition, so balance should not be promised for arbitrary operating conditions. Selection requires the power and electrical characteristics of each output circuit, together with the input voltage and frequency. Mechanical construction is selected according to the rating and process requirements. Provide both load schedules and the expected operating sequence when requesting a proposal. The final design should state the output ratings, connection arrangement and any required regulation. The Scott connection itself should not be confused with a complete independent voltage-control system.
Features and Benefits
- Two phase-displaced outputs serve paired single-phase loads.
- Matched load review helps assess input balance.
Technical Specifications
| Model number |
Rated capacity (kVA) |
Phase number |
Rated voltage (V) |
Connection symbol |
Loss (W) |
No load current (%) |
Impedance voltage (%) |
Overall dimensions Length x Width x Height (mm) |
||
|---|---|---|---|---|---|---|---|---|---|---|
|
Primary voltage (V) |
Secondary (V) |
No-load | Short circuit | |||||||
| S/D-20 | 20 | 3 | 380 |
Choose freely according to user requirements |
T | 180 | 630 | 3.8 | 4 | 580×320×550 |
| S/D-30 | 30 | 3 | 380 | T | 240 | 960 | 3.5 | 4 | 630×350×560 | |
| S/D-40 | 40 | 3 | 380 | T | 280 | 1120 | 3.1 | 4 | 670×380×600 | |
| S/D-50 | 50 | 3 | 380 | T | 330 | 1400 | 2.85 | 4 | 720×400×600 | |
| S/D-60 | 60 | 3 | 380 | T | 350 | 1530 | 2.8 | 4 | 780×400×620 | |
| S/D-80 | 80 | 3 | 380 | T | 420 | 1720 | 2.7 | 4 | 850×430×700 | |
| S/D-100 | 100 | 3 | 380 | T | 520 | 2080 | 2.6 | 5 | 900×450×720 | |
| S/D-120 | 120 | 3 | 380 | T | 580 | 2320 | 2.6 | 5 | 920×450×800 | |
| S/D-160 | 160 | 3 | 380 | T | 650 | 2600 | 2.5 | 5 | 960×480×850 | |
| S/D-180 | 180 | 3 | 380 | T | 730 | 2920 | 2.3 | 5 | 960×500×900 | |
| S/D-200 | 200 | 3 | 380 | T | 920 | 3500 | 2.1 | 5 | 1020×500×900 | |
| S/D-240 | 240 | 3 | 380 | T | 1120 | 4480 | 1.8 | 5.5 | 1150×500×930 | |
| S/D-300 | 300 | 3 | 380 | T | 1800 | 7200 | 1.6 | 5.5 | 1200×520×950 | |
| S/D-400 | 400 | 3 | 380 | T | 2600 | 9100 | 1.3 | 5.5 | 1310×550×1100 | |
* Values are reference data; project guarantees are confirmed in the technical agreement.
Packing & Delivering
Multi-layer protection and expert logistics for safe global transit.
FAQ's
Q: How Are Price And Lead Time Confirmed?
A: They are confirmed after reviewing the specification and quantity.
Q: What Information Is Needed For A Quotation? (Scott-T Transformer)
A: Two output load powers; load characteristics; simultaneous operation; input supply; control.
Q: Will It Balance Any Unequal Loads?
A: No. Input balance depends on the two output loads and their operating characteristics.
How Does A Scott-T Transformer Affect Balance?
A Scott connection provides two single-phase outputs with a 90-degree displacement. Similar loading and power factors help maintain three-phase input balance. Unequal output loads alter that condition, so both load schedules are required for selection.