Magnetic Voltage Regulator
Overview
Magnetic voltage regulators are a core Milky Way product for glass melting, industrial furnaces and advanced-material heating. DC excitation changes the magnetic operating condition to provide smooth, stepless voltage adjustment under load, without a mechanical drive or regulating contacts. The voltage range and control arrangement are matched to processes where heat input must change with temperature, load resistance or the production stage.
Configuration and Control
- Single-phase, three-phase and Scott-connected arrangements are available to match the supply and load. A Scott arrangement converts a three-phase supply into two-phase outputs, with output regulation configured for the project. Manual open-loop operation or closed-loop regulation using control signals can be specified. Control targets, feedback, interlocks and protection interfaces are coordinated in the technical design.
Applications
- Glass melting and electric boosting; glass-fiber, ceramic-fiber and refractory-material processing; resistance heating and heat treatment; and selected salt bath, vacuum and electroslag furnace duties. Voltage, phase arrangement and duty are selected for the actual process.
Technical Specifications
Configurable ratings include capacity, input voltage, output voltage range, phases and connections, output current, frequency, cooling, insulation, control signals and installation interfaces. Process operating curves allow the voltage and current at different duty points to be reviewed.
| Specification model |
Rated capacity (kVA) |
Rated input voltage (V) |
Output voltage range (V) |
Phase number |
DC Control voltage (V) |
DC control current (A) |
Weight (kg) |
Overall dimensions (L × W × H), mm |
|---|---|---|---|---|---|---|---|---|
| TDH2-20/0.5 | 20 | 380 |
5-35 10-70 |
Single-phase | 380 | 5 | 505 | 1020×770×930 |
| TDH2-30/0.5 | 30 | 530 | 10 | 740 | 1080×900×1140 | |||
| TDH2-40/0.5 | 40 | 650 | 10 | 860 | 1125×870×1290 | |||
| TDH2-50/0.5 | 50 | 720 | 10 | 1010 | 1160×900×1400 | |||
| TDH2-63/0.5 | 63 | 920 | 10 | 1215 | 1235×1040×1585 | |||
| TDH2-80/0.5 | 80 | 1100 | 15 | 1470 | 1290×1060×1535 | |||
| TDH2-100/0.5 | 100 | 1320 | 20 | 1720 | 1240×1030×1575 | |||
| TDH2-125/0.5 | 125 | 1650 | 20 | 1970 | 1285×1050×1675 | |||
| TDH2-160/0.5 | 160 | 1680 | 20 | 2385 | 1325×1100×1735 | |||
| TDH2-200/0.5 | 200 | 2030 | 20 | 3065 | 1525×1205×1860 | |||
| TDH2-250/0.5 | 250 | 2090 | 20 | 3520 | 1585×1205×2040 | |||
| TDH2-315/0.5 | 315 | 3050 | 40 | 4490 | 1715×1280×2200 | |||
| TDH2-400/10 | 400 | 1000 |
20-140 40-280 |
3180 | 40 | 5230 | 2370×1295×2748 | |
| TDH2-500/10 | 500 | 3840 | 40 | 5865 | 2450×1325×2780 | |||
| TDH2-630/10 | 630 | 3640 | 40 | 7250 | 2450×1395×2890 | |||
| TDH2-800/70 | 800 | 4500 | 40 | 8755 | 2750×1650×3180 | |||
| TDH2-1000/10 | 1000 | 5000 | 40 | 10100 | 2850×1800×3245 | |||
| TDH2-1600/6.3 | 1600 | 6300 | 25-85 | 6120 | 60 | 14600 | 3970×2590×3800 | |
| TDH2-2000/6.3 | 2000 | 6600 | 40-95 | 7500 | 60 | 14100 | 3100×1925×3850 | |
| TDH2-2600/10 | 2600 | 10000 | 30-90 | 15000 | 60 | 13500 | 3180×1950×3000 | |
| TDH2-3000/10 | 3000 | 10000 | 30-95 | 16000 | 60 | 16500 | 3280×1925×3100 | |
| TDH2-3150/10 | 3150 | 10000 | 40-120 | 10500 | 60 | 17000 | 2400×1925×3600 | |
| TDGH-30/0.5 | 30 | 380 | 5-30 | 470 | 7 | 400 | 880×400×795 | |
| TDGH-50/0.5 | 50 | 380 | 5-35 | 630 | 7 | 750 | 1080×515×885 | |
| TDGH-80/0.5 | 80 | 380 | 5-35 10-70 | 700 | 10 | 1085 | 1450×620×1540 | |
| TDGH-150/10 | 150 | 380 | 500-6000 | 1300 | 20 | 2300 | 1750×800×1800 | |
| TSGH-50/0.5 | 50 | 380 | 6-60 | Three-phase | 600 | 10 | 850 | 1500×620×1375 |
| TSGH-63/0.5 | 63 | 380 | 8-80 | 600 | 15 | 1200 | 1580×666×1540 | |
| TSGH-80/0.5 | 80 | 380 | 10-75 | 800 | 11 | 1600 | 1440×700×1860 | |
| TSGH-90/0.5 | 90 | 380 | 7-70 | 700 | 10 | 1400 | 1600×680×1550 | |
| TSGH-100/0.5 | 100 | 380 | 7-70 | 900 | 10 | 1500 | 1630×680×1650 | |
| TSGH-125/0.5 | 125 | 380 | 7-70 | 1190 | 20 | 2000 | 1785×720×1800 | |
| TSGH-160/0.5 | 160 | 380 | 10-75 | 1400 | 16 | 2500 | 1650×760×1800 | |
| TSGH-200/0.5 | 200 | 380 | 10-75 | 1800 | 20 | 3200 | 1800×800×1920 | |
| TSGH-250/0.5 | 250 | 380 | 10-75 | 1960 | 20 | 3800 | 2170×880×2130 | |
| TSH-35/0.5 | 35 | 380 |
5-17.5 5-20 5-30 5-35 5-40 10-60 10-70 |
600 | 3 | 935 | 1020×840×1450 | |
| TSH-50/0.5 | 50 | 380 | 735 | 7 | 1315 | 1000×920×1760 | ||
| TSH-63/0.5 | 63 | 380 | 1100 | 15 | 1550 | 1100×920×1760 | ||
| TSH-80/0.5 | 80 | 380 | 770 | 10 | 1685 | 1100×1090×1570 | ||
| TSH-100/0.5 | 100 | 380 | 850 | 10 | 1900 | 1075×1086×1645 | ||
| TSH-125/0.5 | 125 | 380 | 1500 | 20 | 2100 | 1170×1200×1760 | ||
| TSH-150/0.5 | 150 | 380 | 10000 | 20 | 2500 | 1075×1216×1775 | ||
| TSH-160/0.5 | 160 | 380 | 1700 | 20 | 2440 | 1200×1220×1815 | ||
| TSH-200/0.5 | 200 | 380 | 1800 | 20 | 3000 | 1230×1240×2020 | ||
| TSH-250/0.5 | 250 | 380 | 2400 | 20 | 3250 | 1520×1250×2120 | ||
| TSH-315/0.5 | 315 | 380 | 2700 | 20 | 3885 | 1300×1310×2230 | ||
| TSH-400/0.5 | 400 | 380 | 40-100 | 3000 | 20 | 4835 | 1500×1360×2258 | |
| TSH-500/0.5 | 500 | 380 | 37-260 | 5760 | 40 | 5130 | 1820×1360×2222 | |
| TSH-630/0.5 | 630 | 1000 | 20-100 | 6000 | 40 | 7320 | 2370×1600×3220 | |
| TSH-750/0.5 | 750 | 380 | 50-300 | 5500 | 40 | 8000 | 1940×1480×2720 | |
| TSH-800/0.5 | 800 | 380 | 40-360 | 5800 | 50 | 8400 | 2020×1530×2670 | |
| TSH-1000/10 | 1000 | 10000 | 40-170 | 8500 | 40 | 8760 | 2550×1860×3300 | |
| TSH-1250/10 | 1250 | 10000 | 36-250 | 10200 | 60 | 12900 | 2770×2000×3240 | |
| TSH-1560/10 | 1560 | 10000 | 30-160 | 11700 | 50 | 14800 | 3310×3280×2800 | |
| TSH-2100/10 | 2100 | 10000 | 35-310 | 13000 | 60 | 15600 | 3460×2450×2700 | |
| TSH-3000/10 | 3000 | 10000 | 80-260 | 15000 | 60 | 17500 | 3525×2450×2820 | |
| TSHP-4000/10 | 4000 | 10000 | 35-130 | 25000 | 100 | 22600 | 2350×2860×3070 | |
| TTH-250/0.5 | 250 | 380 | 15-125 | 3560 | 20 | 3250 | 1830×1400×1750 | |
| TTH-500/6 | 500 | 6000 | 20-110 | 6350 | 40 | 5800 | 2200×1900×2900 | |
| TTH-630/10 | 630 | 10000 | 20-110 | 7560 | 40 | 6920 | 2450×2320×3080 |
* Values are reference data; project guarantees are confirmed in the technical agreement.
Packing & Delivering
Multi-layer protection and expert logistics for safe global transit.
FAQ's
Q: What Information Is Needed For Selection?
A: Send supply voltage, phases, frequency, load type, maximum power, the full operating voltage-current range and control requirements. For retrofits, include the existing nameplate and connection diagram.
Q: Can It Work With An Existing Temperature-control System?
A: The arrangement can be configured around the control and feedback requirements. Please provide the controller interfaces, load data and interlock requirements.
Q: How Does It Differ From A Fixed-output Transformer?
A: A magnetic voltage regulator adjusts output voltage during operation for processes requiring continuous power adjustment. A fixed-output transformer primarily provides a defined voltage transformation.
What belongs in a custom transformer RFQ?
Include the application, capacity or load power, input and output voltage, phase, frequency and quantity. Add the adjustment range, duty cycle, cooling, environment, dimensions and connection requirements. If the specification is incomplete, start with an application description and available drawings for technical discussion.
Can A Magnetic Regulator Serve Continuous-duty Applications?
Continuous industrial duty is covered in the source applications, but the rating must be established with the cooling and installation environment. Furnace temperature is not the same as ambient air temperature at the transformer. Provide the actual local temperature, ventilation and contamination conditions for design review.
What Data Is Needed For A Furnace Regulator?
Provide input voltage and frequency, output voltage and current across operating stages, load type, control mode and duty cycle. Include cooling conditions, ambient temperature, space restrictions and cabinet interfaces. For replacement equipment, add the nameplate, connection diagram and the issue being addressed.
Magnetic Regulator, Thyristor Controller Or OLTC?
Compare these options against the actual load, adjustment range, adjustment frequency, waveform requirements and maintenance conditions. Magnetic regulators use excitation control; thyristor systems use power electronics; OLTC systems change tap positions. Losses and control performance should be compared for the specified complete systems, not inferred from the technology name.
How Does Contactless Magnetic Voltage Control Work?
DC excitation changes the magnetic operating condition and therefore the output. Contactless refers to the regulating principle; it does not mean the complete installation contains no switches or needs no maintenance. Specify manual or closed-loop operation, feedback signals and the variable to be controlled.
What Is A Magnetic Voltage Regulator?
A magnetic voltage regulator uses DC excitation to control its magnetic circuit and adjust the AC output smoothly within the specified range. Selection considers both voltage and current throughout the operating cycle. The control arrangement must be coordinated with the industrial load and its controller.