Electric Arc Furnace Transformer
Overview
The steelmaking duty defines the required load cycle, mechanical duty and regulation arrangement. Reactor requirements must be coordinated with the furnace system. A furnace transformer supplies electrical power to an industrial furnace according to its process requirements. The reference catalogue covers submerged arc, steelmaking arc, ladle refining, electroslag and power-frequency furnace applications. These duties should be treated separately because their operating cycles, secondary voltages and regulation requirements differ. The selection process starts with the furnace type, rated power and required output range. Input voltage, phase arrangement, impedance requirements and cooling conditions are then reviewed with the furnace equipment supplier. Available catalogue tables provide reference configurations for each family, including ratings, dimensions and weights where stated. A listed configuration is not a promise that it fits every furnace with the same nominal capacity. For a new furnace or replacement project, send the electrical specification, operating cycle and connection requirements. The technical proposal will define the selected transformer arrangement and accessories. Installation dimensions and lifting requirements should be confirmed against the approved project drawing before site work begins.
Features and Benefits
- Furnace-specific selection matches the electrical process.
- Dedicated reference tables allow comparison of relevant configurations.
Technical Specifications
| Model number |
Rated capacity (kVA) |
Rated voltage | Connection symbol |
Product weight (kg) |
Track gauge (mm) |
Overall dimensions (L × W × H), mm | |||
|---|---|---|---|---|---|---|---|---|---|
|
Primary voltage (kV) |
Secondary (V) |
Body weight | Oil weight | Gross weight | |||||
| HSK-260/0.5 | 260 | 0.4 | 95-110 | Yd11 | 800 | 420 | 1600 | 700×600 | 1200×800×1450 |
| HSK-280/0.5 | 280 | 0.4 | 95-110 | Yd11 | 840 | 420 | 1670 | 700×600 | 1200×800×1550 |
| HSK-300/0.5 | 300 | 0.4 | 95-110 | Yd11 | 870 | 510 | 1830 | 700×600 | 1250×800×1550 |
| HSK-315/0.5 | 315 | 0.4 | 95-110 | Yd11 | 930 | 560 | 2180 | 750×700 | 1250×870×1580 |
| HSK-360/0.5 | 360 | 0.4 | 110 | Yd11 | 1080 | 630 | 2360 | 800×750 | 1360×910×1600 |
| HSK-400/0.5 | 400 | 0.4 | 95-190 | Yd11 | 1150 | 670 | 2730 | 800×800 | 1360×950×1700 |
| HSK-400/6 | 400 | 6 | 105-90-90-75-60.6-52-52-43.3 | D-Yd0-11 | 1360 | 930 | 3010 | 820×820 | 2150×1230×2200 |
| HSK-630/10 | 630 | 10 | 180 | Yyn0 | 1280 | 800 | 2950 | 820×820 | 1600×1150×1900 |
| HSZ-800/10 | 800 | 10 | 200-100 | Yyn0 | 1620 | 830 | 3260 | 820×820 | 2250×1350×2200 |
| HSK-800/10 | 800 | 10 | 200-170-115-98 | D-Yd0-11 | 2250 | 1600 | 5250 | 820×820 | 2250×1365×2980 |
| HSK-1000/10 | 1000 | 10 | 200-200-170-115-115-98 | D-Yd0-11 | 2510 | 1790 | 5800 | 850×850 | 2290×1555×3050 |
| HSK-1250/10 | 1250 | 10 | 210-180-180-121-104-104 | D-Yd0-11 | 2850 | 2150 | 6880 | 1050×1050 | 2700×1760×3100 |
| HSSP-1400/10 | 1400 | 10 | 220-220-190-127-127-110 | D-Yd0-11 | 3300 | 1850 | 6800 | 1050×1050 | 2700×2050×2800 |
| HSK-1600/10 | 1600 | 10 | 210-210-180-121-121-104 | D-Yd0-11 | 3530 | 2445 | 7860 | 1070×1070 | 2960×1760×3170 |
| HSSPK-1800/35 | 1800 | 35 | 222-206-190-174-158-128 | Yd11 | 5200 | 3800 | 13800 | 1505×1505 | 2850×1900×3800 |
| HSZ-2000/6.3 | 2000 | 6.3 | 240-220-180-160-140-120 | Ya0Dd0 | 4100 | 2750 | 9050 | 1070×1505 | 3000×2390×2620 |
| HS-2200/10 | 2200 | 10 | 222-220-190-127-110 | D-Yd0-11 | 4530 | 2800 | 10000 | 1070×1070 | 3250×2550×2900 |
| HS-2500/10 | 2500 | 10 | 240-240-210-170-138-121 | D-Yd0-11 | 5460 | 3200 | 11800 | 1070×1070 | 3400×2500×3100 |
| HSK-3150/10 | 3150 | 10 | 220-220-170-121-121-98 | D-Yd0-11 | 5795 | 4150 | 13450 | 1435×1435 | 3440×2375×3800 |
| HSSPK-4000/10 | 4000 | 10 | 240-240-210-138-121 | D-Yd0-11 | 6400 | 3200 | 12600 | 1435×1435 | 3150×2900×3300 |
| HSSPK-4000/35 | 4000 | 35 | 240-240-210-138-136-121 | D-Yd0-11 | 7700 | 5800 | 17900 | 1435×1435 | 3150×2900×3300 |
| HSSPK-5500/6 | 5500 | 6 | 260-139 6 steps | D-Yd0-11 | 9500 | 4200 | 17000 | 1435×1435 | 3200×2100×3350 |
| HSSPK-5500/10 | 5500 | 10 | 260-245-232.5-210-150-141.5-134-121 | D-Yd0-11 | 7800 | 3800 | 13400 | 1435×1435 | 3070×2000×3120 |
| HSSPK-5500/10 | 5500 | 10 | 263-247.5-235-211-152-143-136-122 | D-Yd0-11 | 8140 | 3860 | 13850 | 1435×1435 | 3100×2000×3120 |
| HSSPK-5500/35 | 5500 | 35 | 260-245-232.5-210-150-141.5-134-121 | D-Yd0-11 | 9800 | 5500 | 17700 | 1435×1435 | 3650×2100×3570 |
| HSSPK-6300/10 | 6300 | 10 | 260-260-240-139-150 | D-Yd0-11 | 9000 | 4015 | 15500 | 1435×1435 | 3100×2100×3400 |
| HSSPK-6300/10 | 6300 | 10 | 260-150 8 steps | D-Yd0-11 | 12500 | 4800 | 19000 | 1435×1435 | 3050×2465×3200 |
| HSSPK-6300/35 | 6300 | 35 | 260-139 5 steps | D-Yd0-11 | 11500 | 5500 | 21000 | 1435×1435 | 3600×2200×3680 |
| HSSPK-6300/35 | 6300 | 35 | 260-260-240-210-150-139-121 | D-Yd0-11 | 11330 | 5300 | 20000 | 1435×1435 | 3570×2200×3660 |
| HSSPK-8000/10 | 8000 | 10 | 285-121 7 steps | D-Yd0-11 | 12000 | 4300 | 18000 | 1435×1435 | 3200×2150×3400 |
| HSSP-8000/10 | 8000 | 10 | 280-260-230-133-150-162 | D-Yd0-11 | 9300 | 4600 | 17000 | 1435×1435 | 3300×2200×3400 |
| HSSPZ-8000/35 | 8000 | 35 | 270-139 9 steps | Yd11 | 12000 | 9100 | 27000 | 1435×1435 | 3600×2180×3600 |
| HSSP-9000/10 | 9000 | 10 | 280-260-220-160-150-127 | D-Yd0-11 | 12200 | 7640 | 25000 | 1435×1435 | 3800×2250×4200 |
| HSSP-9000/35 | 9000 | 35 | 320-256-233-185-148-135 | D-Yd0-11 | 12600 | 8400 | 27500 | 1435×1435 | 3900×2700×4500 |
| HSSPZ-10000/35 | 10000 | 35 | 300-140 19 steps | Yd11 | 13800 | 9400 | 30000 | 1435×1435 | 4450×2700×4300 |
| HSSPZ-10000/35 | 10000 | 35 | 300-280-140 9 steps | Yd11 | 14800 | 9500 | 28500 | 1435×1435 | 4280×2800×4100 |
| HSSPZ-12500/35 | 12500 | 35 | 340-15 19 steps | Yd11 | 18000 | 11800 | 39000 | 1435×1435 | 4800×3200×4800 |
| HSSP-12500/35 | 12500 | 35 | 365-230 9 steps | Yd11 | 18400 | 8100 | 33500 | 1435×1435 | 3600×3200×4300 |
| HSSP-12500/35 | 12500 | 35 | 350-297-137 13 steps | Yd11 | 19500 | 10000 | 34800 | 1435×1435 | 3600×3450×4320 |
| HSSPZ-12500/35 | 12500 | 35 | 350-210 9 steps | Yd11 | 18200 | 9900 | 35000 | 1435×1435 | 4000×3200×4400 |
| HSSPZ-15000/35 | 15000 | 35 | 390-150 9 steps | Yd11 | 24000 | 12000 | 39800 | 1435×1435 | 3400×3950×4100 |
| HSSPZ-16000/35 | 16000 | 35 | 360-140 19 steps | Yd11 | 21500 | 13000 | 47000 | 1435×1435 | 4550×3300×4900 |
| HSSPZ-18000/35 | 18000 | 35 | 400-320-220 13 steps | Yd11 | 25600 | 13800 | 45700 | 1435×1435 | 3950×3010×4300 |
| HSSPZ-20000/35 | 20000 | 35 | 392-158 19 steps | Yd11 | 27600 | 15000 | 53000 | 1435×1435 | 4600×3900×5000 |
| HSSPZ-24000/35 | 24000 | 35 | 550-410-298 19 steps | Yd11 | 31800 | 15000 | 58000 | 1435×1435 | 5100×3350×4800 |
| HSSPZ-25000/35 | 25000 | 35 | 436-184 19 steps | Dd0 | 34000 | 19000 | 66800 | 1435×1435 | 4600×3900×5300 |
| HSSPZ-25000/35 | 25000 | 35 | 610-524-350 13 steps | Yd11 | 31000 | 15200 | 59000 | 1435×1435 | 4900×3400×4600 |
| HSSPZ-25000/35 | 25000 | 35 | 570-430-350 13 steps | Yd11 | 28900 | 13000 | 46000 | 1435×1435 | 4900×2700×4700 |
| HSSPZ-28000/35 | 28000 | 35 | 460-240 13 steps | Yd11 | 32000 | 15800 | 60000 | 1435×1435 | 5200×3100×4900 |
| HSSP-30000/35 | 30000 | 35 | 710-620-350 13 steps | Yd11 | 41000 | 17500 | 62000 | 1435×1435 | 3400×3800×4600 |
| HSSPZ-31500/35 | 31500 | 35 | 489-201 19 steps | Dd0 | 42240 | 21700 | 75600 | 2000×2000 | 5000×4000×6000 |
| HSSPZ-32000/35 | 32000 | 35 | 650-500-350 13 steps | Yd11 | 37800 | 10000 | 62500 | 2000×2000 | 4800×3750×5100 |
| HSSPZ-35000/35 | 35000 | 35 | 670-520-320 15 steps | Yd11 | 39000 | 18500 | 66000 | 2000×2000 | 5200×3800×5000 |
| HSSPZ-40000/35 | 40000 | 35 | 610-510-350 13 steps | Dd0 | 38000 | 18000 | 63500 | 2000×2000 | 4500×3300×5100 |
| HSSPZ-40000/35 | 40000 | 35 | 547-223 19 steps | Dd0 | 39600 | 25600 | 88600 | 2000×2000 | 5600×4000×6100 |
| HSSPZ-45000/35 | 45000 | 35 | 750-650-450 19 steps | Yd11 | 42800 | 26500 | 92000 | 2000×2000 | 5600×4080×6150 |
* Values are reference data; project guarantees are confirmed in the technical agreement.
Packing & Delivering
Multi-layer protection and expert logistics for safe global transit.
FAQ's
Q: What Determines The Correct Model?
A: The process duty and electrical specification, rather than the product name alone.
Q: Are All Catalogue Values Guaranteed For A New Project?
A: The selected configuration and guaranteed values must be agreed in the technical specification.
Q: What Should I Send For A Quotation? (Electric Arc Furnace Transformer) (Submerged Arc Furnace Transformer)
A: Furnace type; capacity; input/output voltage; duty cycle; tap control; cooling.