Products
Special Transformers

Submerged Arc Furnace Transformer

Submerged Arc Furnace Transformer
Submerged Arc Furnace Transformer

Overview

Continuous smelting duty requires the output voltage steps and current schedule to be matched to the furnace. The source catalogue distinguishes on-load and off-circuit regulation. A furnace transformer supplies electrical power to an industrial furnace according to its process requirements. The reference catalogue covers submerged arc, steelmaking arc, ladle refining, electroslag and power-frequency furnace applications. These duties should be treated separately because their operating cycles, secondary voltages and regulation requirements differ. The selection process starts with the furnace type, rated power and required output range. Input voltage, phase arrangement, impedance requirements and cooling conditions are then reviewed with the furnace equipment supplier. Available catalogue tables provide reference configurations for each family, including ratings, dimensions and weights where stated. A listed configuration is not a promise that it fits every furnace with the same nominal capacity. For a new furnace or replacement project, send the electrical specification, operating cycle and connection requirements. The technical proposal will define the selected transformer arrangement and accessories. Installation dimensions and lifting requirements should be confirmed against the approved project drawing before site work begins.

Request a Quote

Features and Benefits

  • Furnace-specific selection matches the electrical process.
  • Dedicated reference tables allow comparison of relevant configurations.

Technical Specifications

Model number Rated capacity
(kVA)
Rated voltage Connection symbol  Product weight
(kg)
Track gauge
(mm)
Overall dimensions (L × W × H), mm
Primary voltage
(kV)
Secondary
(V)
Body weight Oil weight Gross weight
HKSSP-880/10 800 10 120-105-85-70 4 Yd11 2700 1880 5950 1070×1070 2500×1500×2500
HKSSP-1000/10 1000 10 80-60 7 steps Yd11 2830 1650 5950 1070×1070 1600×1300×2500
HKSSP-1250/10 1250 10 90-60-50 5 steps Yd11 4100 2850 9800 1070×1070 3200×1700×2500
HKS-1250/10 1250 10 130-105 6 steps Yd11 3330 1940 7000 1070×1070 2900×2250×2160
HKSSP-1500/35 1500 35 240-210-135 12 steps Yd11 4350 3900 12600 1435×1435 3900×1800×2800
HKS-1650/10 1650 10 140-100 6 steps Yd11 4240 2470 8900 1070×1070 2940×1950×2300
HSKZ-1800/10 1800 10 160-141-126 9 steps Yd11 4290 2500 9000 1435×1435 2800×1800×3250
HKSSP-2000/35 2000 35 240-150 9 steps Yd11 5200 3600 12400 1435×1435 3600×1700×2700
HKSSP-2500/6 2500 6 104-80 11 steps Yd11 6100 3800 14200 1070×1070 4000×2100×2800
HTSSP-2500/10 2500 10 98.5-95-83 5 steps Yd11 6190 3610 13000 1435×1435 2810×1880×3360
HTSSP-2500/35 2500 35 88-76-70 5 steps Dd0 6670 3890 14000 1435×1435 3780×1950×3450
HKSZ-3000/10 3000 10 410-350-190 23 steps Yd11 7430 4330 15600 1435×1435 4020×2650×4000
HTSSP-3200/10 3200 10 220-110 13 steps Yd11 6900 4030 14500 1435×1435 4050×2550×2900
HKSSP-3200/35 3200 35 250-150 21 steps Yd11 6800 4750 16000 1435×1435 4100×2300×4000
HKSSP-3500/35 3500 35 114-92-84 5 steps Yd11 7140 4170 15000 1435×1435 3800×2050×3250
HTSSP-3500/35 3500 35 112-102-84 5 steps Yd11 7480 4360 15700 1435×1435 3750×2150×3350
HKSSP-3500/35 3500 35 230-160 15 steps Yd11 8800 6250 19500 1435×1435 4100×3000×3800
HKSSP-3500/35 3500 35 250-210-170 9 steps Yd11 7428 4500 15800 1435×1435 4000×2050×4000
HKSSP-4000/10 4000 10 120-96-80 7 steps Yd11 6810 3970 14300 1435×1435 3680×1900×3000
HKSSP-4000/10 4000 10 123-105-93 6 steps Yd11 7330 4280 15400 1435×1435 3850×2250×3000
HKSSP-4500/35 4500 35 120-105-90 7 steps Yd11 8100 4720 17000 1435×1435 4100×1950×3350
HKSSP-4500/10 4500 10 126-109-96 5 steps Yd11 8570 5000 18000 1435×1435 4050×2250×3350
HCSSP-5000/10 5000 10 124-71 8 steps Yd11 10000 5830 21000 1435×1435 4100×2280×3300
HKSSPZ-5000/10 5000 10 200-176-120 11 steps Yd11 9200 5100 17200 1435×1435 4000×2300×4200
HKSSP-5000/35 5000 35 132-95 7 steps Dd0 10950 6390 23000 1435×1435 4280×2700×4000
HKSSPZ-5000/35 5000 35 197-109-60 19 steps Yd11 12380 7220 26000 2000×2000 4450×2850×4120
HKSSP-6300/10 6300 10 190-135-110 5 steps Yd11 9500 4500 18200 1435×1435 3800×2300×4100
HKSSPZ-6300/20 6300 20 138-120-104 18 steps Yd11 11500 4850 18520 1435×1435 4000×2100×4100
HTSSP-6300/35 6300 35 130-118-94 7 steps Dd0 10950 6390 23000 1435×1435 4170×2640×3600
HKSSP-6300/35 6300 35 125-119-85 7 steps Dd0 12380 7220 26000 1435×1435 4890×2410×3600
HTSSPZ-6300/35 6300 35 135-119-104 7 steps Yd11 12860 7500 27000 1435×1435 4455×2850×3980
HCSSP-6300/35 6300 35 133-100 11 steps Dd0 10520 5830 21000 1435×1435 4750×2350×3870
HKSSPZ-7000/20 7000 20 150-126-102 17 steps Yd11 11000 7500 22500 1435×1435 4100×2400×4200
HKSSP-7000/35 7000 35 136-120-104 7 steps Dd0 10000 5830 21000 1435×1435 4885×2300×3800
HTSSP-7000/35 7000 35 132-112-100 9 steps Dd0 10300 6000 21500 1435×1435 4650×2400×3780
HCSSP-7000/35 7000 35 135-112-104 9 steps Dd0 10240 5970 21500 1435×1435 4700×2300×3800
HTSSP-7500/35 7500 35 135-125-104 8 steps Dd0 9520 5560 20000 1435×1435 4300×2200×3850
HKSFPZ-7500/35 7500 35 148-133-188 9 steps Dd0 15710 9170 33000 1435×1435 4350×2400×3780
HCSFPZ-8000/35 8000 35 136-120-108 13 steps Yd11 12800 6960 25600 1435×1435 4200×2600×3800
HCSFPZ-8000/35 8000 35 143-126-108 15 steps Yd11 13800 7500 27600 1435×1435 5140×2800×4040
HCSSPZ-8000/35 8000 35 136-120-108 7 steps Dd0 11900 6940 25000 1435×1435 4200×2650×3800
HTSFP-8000/35 8000 35 147-126-110 8 steps Dd0 12380 7220 26000 1435×1435 3750×2800×3980
HKSSPZ-8000/66 8000 66 145-124-115 9 steps Yd11 18100 10560 38000 1435×1435 4500×3300×5200
HTSSPZ-9000/35 9000 35 158-128-110 13 steps Yd11 13810 8060 29000 1435×1435 4300×2050×4300
HCSFPZ-10000/35 10000 35 156-131-105 17 steps Yd11 18500 10050 37000 1435×1435 3800×2800×4400
HCSFPZ-10000/35 10000 35 157-131-118 13 steps Yd11 16600 9020 33200 1435×1435 4440×2800×3890
HCSFPZ-10000/35 10000 35 160-148-120 15 steps Yd11 16250 8830 32500 1435×1435 4200×2800×3800
HKSSPZ-10000/35 10000 35 171-132-123 9 steps Dd0 14050 8190 29500 1435×1435 3800×2800×4650
HCSSPZ-10000/35 10000 35 160-130-115 17 steps Dd0 14760 8610 31000 1435×1435 3900×2800×4800
HCSSPZ-12000/35 12000 35 152-126-114 17 steps Yd11 19750 10730 39500 1435×1435 4270×2823×4535
HCSFPZ-12500/35 12500 35 160-145-124 15 steps Yd11 19700 10710 39400 1435×1435 3840×2800×4170
HCSFPZ-12500/35 12500 35 175-153-134 13 steps Yd11 17800 9670 35600 1435×1435 4000×2800×4000
HKSSPZ-12500/35 12500 35 190-110 17 steps Yd11 23000 12500 46000 1435×1435 4200×2800×4500
HKSSP-12500/35 12500 35 365-265-153 9 steps Yd11 15700 9200 33000 1435×1435 4500×2800×4580
HTSSP-12500/35 12500 35 166-140-126 9 steps Yd11 15710 9170 33000 1435×1435 3800×2400×4600
HCSSP-12500/35 12500 35 175-153-134 9 steps Yd11 15240 8890 32000 1435×1435 3980×2870×3900
HKSSP-12500/35 12500 35 400-300-200 17 steps Yd11 23000 11200 42500 1435×1435 4300×3400×4500
HTSSPZ-14000/35 14000 35 180-135-120 13 steps Yd11 17140 10000 36000 1435×1435 3900×2950×4680
HCSSPZ-14500/35 14500 35 185-167-137 13 steps Yd11 17620 10280 37000 1435×1435 4900×2800×4750
HKSSPZ-15000/35 15000 35 176-152-122 19 steps Yd11 25400 14000 52000 1435×1435 4500×3200×4600
HKSSP-15000/35 15000 35 370-313-295 13 steps Yd11 15710 9170 33000 1435×1435 4600×2850×4100
HTSSP-15000/35 15000 35 167-151-127 9 steps Dd0 16670 9720 35000 1435×1435 3800×2900×4650
HCSSP-16500/35 16500 35 170-149 7 steps Dd0 19050 11110 40000 1435×1435 5250×2900×4500
HTSSPZ-16500/35 16500 35 178-154-136 8 steps Dd0 18570 10830 39000 1435×1435 3635×3180×4700
HKSSP-16500/35 16500 35 300-250-195 19 steps Yd11 24200 12500 44000 1435×1435 4300×3450×4560
HKSSP-16500/35 16500 35 420-336-261 13 steps Yd11 18100 10560 38000 1435×1435 4860×2830×4650
HKSSP-18000/35 18000 35 430-360-260 13 steps Yd11 18330 10690 38500 1435×1435 5150×2850×4430
HCSSPZ-18000/35 18000 35 180-158-135 13 steps Dd0 22380 13060 47000 1435×1435 4300×3890×4750
HKSSP-20000/35 20000 35 410-325-237 27 steps Dd0 20950 12220 44000 1435×1435 5100×2800×4750
HCSFPZ-20000/35 20000 35 185-171-134 9 steps Dd0 20480 11940 43000 1435×1435 4050×3560×4560
HKSSP-23000/35 23000 35 445-360-265 27 steps Dd0 22860 13330 48000 1435×1435 5350×2850×4700
HCSFPZ-25000/35 25000 35 224-187-148 13 steps Yd11 28570 16670 60000 1435×1435 5000×3920×4700
HTSSPZ-25000/35 25000 35 240-180-140 35 steps Yd11 39000 21000 76000 2000×2000 4800×3800×5400
HKSFPZ-25000/35 25000 35 480-375-190 35 steps Yd11 31430 18330 66000 1435×1435 6050×3800×4550
HCSFPZ-27500/35 27500 35 239-189-144 13 steps Yd11 32860 19170 69000 1435×1435 4350×3800×4500
HKDSPZ-3000/10 3000 10 110-50 15 steps Ii0 6500 3800 13500 1435×1435 3200×2400×2900
HCDSPZ-4200/35 4200 35 170-152-122 7 steps Ii0 8420 4320 16000 1435×1435 2655×2700×2930
HTDSPZ-5500/35 5500 35 169-136-121 9 steps Ii0 9520 5560 20000 1435×1435 3400×2950×3900
HCDFPZ-5500/35 5500 35 185-164-117 9 steps Ii0 14740 7570 28000 1435×1435 3100×3300×4560
HKDSPZ-5500/35 5500 35 350-280-200 19 steps Ii0 8200 4800 17600 1435×1435 3400×2400×4200
HKDSPZ-5500/35 5500 35 400-340-300 19 steps Ii0 11000 9100 27000 1435×1435 3100×2800×4100
HCDSPZ-8500/35 8500 35 240-186-113 10 steps Ii0 17900 9200 34000 1435×1435 3550×2980×4200
HCDFPZ-8500/35 8500 35 243-183-146 8 steps Ii0 16320 8380 31000 1435×1435 4185×3000×4410
HCDSPZ-8500/35 8500 35 220-178-129 13 steps Ii0 14740 7570 28000 1435×1435 4400×3210×4410
HKDSPZ-8500/110 8500 110 440-362-286 19 steps Ii0 17600 10900 37000 1435×1435 4100×3300×4800
HCDSPZ-9000/35 9000 35 205-169-121 9 steps Ii0 16320 8380 31000 1435×1435 4100×3015×4450
HCDSPZ-9000/35 9000 35 205-169-161 19 steps Ii0 16750 9100 33500 1435×1435 3500×3100×4450
HCDSPZ-9000/35 9000 35 234-185-136 27 steps Ii0 15900 8640 31800 1435×1435 4300×3200×4800
HKDSPZ-10000/35 10000 35 500-420-300 35 steps Ii0 17600 10000 34000 1435×1435 3400×3000×4400
HCDSPZ-10000/35 10000 35 244-178-120 17 steps Ii0 16840 8650 32000 1435×1435 3540×3100×4800
HCDSPZ-10000/35 10000 35 240-198-140 17 steps Ii0 15790 8110 30000 1435×1435 3600×3210×4950
HKDSPZ-10500/35 10500 35 240-198-138 35 steps Ii0 18000 9600 30500 1435×1435 3420×2900×4200
HCDSPZ-11000/35 11000 35 248-220-157 13 steps Ii0 16840 8650 32000 1435×1435 4200×3250×4100
HTDSPZ-12000/35 12000 35 850-550-250 25 steps Ii0 26000 10500 44000 1435×1435 3900×3100×4300
HTDSPZ-13500/35 13500 35 260-220-109 35 steps Ii0 22000 10500 38000 1435×1435 3300×3300×4400

* Values are reference data; project guarantees are confirmed in the technical agreement.

Packing & Delivering

Multi-layer protection and expert logistics for safe global transit.

Vacuum Packing
Vacuum Foil Packaging
Wooden Case
Solid Wood Export Cases
Global Routes
Worldwide Delivery

FAQ's

Q: What Determines The Correct Model?

A: The process duty and electrical specification, rather than the product name alone.

Q: Are All Catalogue Values Guaranteed For A New Project?

A: The selected configuration and guaranteed values must be agreed in the technical specification.

Q: What Should I Send For A Quotation? (Electric Arc Furnace Transformer) (Submerged Arc Furnace Transformer)

A: Furnace type; capacity; input/output voltage; duty cycle; tap control; cooling.


Inquiry Form

No file chosen
Supported formats: PDF (max 10MB)
  
Thank you. Your inquiry has been received. We will respond within 24 hours.