Overview

Ladle refining uses a low-voltage, high-current supply. The source description specifies fine on-load voltage adjustment to follow furnace conditions. A furnace transformer supplies electrical power to an industrial furnace according to its process requirements. The reference catalogue covers submerged arc, steelmaking arc, ladle refining, electroslag and power-frequency furnace applications. These duties should be treated separately because their operating cycles, secondary voltages and regulation requirements differ. The selection process starts with the furnace type, rated power and required output range. Input voltage, phase arrangement, impedance requirements and cooling conditions are then reviewed with the furnace equipment supplier. Available catalogue tables provide reference configurations for each family, including ratings, dimensions and weights where stated. A listed configuration is not a promise that it fits every furnace with the same nominal capacity. For a new furnace or replacement project, send the electrical specification, operating cycle and connection requirements. The technical proposal will define the selected transformer arrangement and accessories. Installation dimensions and lifting requirements should be confirmed against the approved project drawing before site work begins.

Request a Quote

Features and Benefits

  • Separate tap-changing configurations support different operating requirements.
  • Project-specific electrical and mechanical review supports installation coordination.

Technical Specifications

Model number Rated capacity
(kVA)
Rated voltage Connection symbol  Product weight
(kg)
Track gauge
(mm)
Overall dimensions (L × W × H), mm
Primary voltage
(kV)
Secondary
(V)
Body weight Oil weight Gross weight
HJSSP-2000/6 2000 6 185-140 4 steps Dd0 3050 2250 8000 1070×1070 2100×1620×2590
HJSSP-2200/10 2200 10 180-150 4 steps Dd0 3600 2900 8300 1070×1070 2350×1780×2600
HJSSP-2400/10 2400 10 200-190-180 6 steps Yd11 3550 2100 9230 1070×1070 2400×1670×2750
HJSSP-2500/20 2500 20 175-115 5 steps Yd11 2700 2100 8300 1200×1070 2800×1600×2500
HJSSP-2800/10 2800 10 190-175-160 6 steps Yd11 5000 2750 10300 1070×1070 2800×1900×3300
HJSSP-3150/10 3150 10 210-150 5 steps Yd11 5500 3350 10600 1435×1435 2830×1850×3200
HJSSP-3200/10 3200 10 180-110 5 steps Yd11 5600 2800 11000 1070×1070 3260×1590×2700
HJSSP-3200/35 3200 35 210-195-170 6 steps Yd11 6480 4150 14200 1435×1435 3150×1900×3600
HJSSP-4000/10 4000 10 210-155 4 steps Dd0 6580 4230 13450 1435×1435 3000×2000×3500
HJSSP-4000/33 4000 33 200-185-135 5 steps Yd11 6700 4100 14500 1435×1435 3100×1950×3100
HJSSP-4000/35 4000 35 210-129 5 steps Yd11 7200 4300 1470 1435×1435 3450×1970×3600
HJSSP-5000/10 5000 10 212-195-155 5 steps Yd11 7300 4230 15000 1435×1435 3200×2300×3100
HJSSP-5000/10 5000 10 210-195-180 6 steps Yd11 7030 4300 14500 1435×1435 3200×1950×3400
HJSSP-5000/33 5000 33 210-195-150 5 steps Yd11 8780 5080 18000 1435×1435 3950×2025×3100
HJSSP-5000/35 5000 35 215-196-155 5 steps Yd11 9100 5200 19600 1435×1435 3800×2100×3150
HJSSP-5500/6 5500 6 220-190-160 6 steps Yd11 7700 4600 16000 1435×1435 3800×2300×3100
HJSSP-5500/10 5500 10 230-212-145 6 steps Yd11 7850 4400 16000 1435×1435 3200×2650×3550
HJSSP-5500/10 5500 10 210-195-180-165-121 Dd0 7800 4300 15600 1435×1435 3150×2000×3500
HJSSP-5500/35 5500 35 210-121 6 steps Yd11 9100 5300 18900 1435×1435 3800×2400×3350
HJSSP-5500/35 5500 35 212-195-155 Yd11 8600 5600 17850 1435×1435 3700×2300×3800
HJSSP-6000/10 6000 10 230-206-145 6 steps Yd11 8200 4800 17000 1435×1435 3760×1690×3280
HJSSP-6000/35 6000 35 220-182-145 6 steps Yd11 8450 5100 17500 1435×1435 3810×1970×3170
HJSSP-6000/35 6000 35 220-160 6 steps Yd11 9030 5200 18600 1435×1435 4200×2409×3700
HJSSP-6000/35 6000 35 220-190-160 6 steps Yd11 9160 5400 19000 1435×1435 4600×2300×3800
HJSSP-6000/35 6000 35 225-200-151 6 steps Yd11 11200 5500 21800 1435×1435 3750×2400×3750
HJSSP-6300/10 6300 10 364-313-262 6 steps Yd11 7530 4600 15600 1435×1435 3564×2000×3000
HJSSP-6300/33 6300 33 215-189-150 6 steps Yd11 9200 5100 19500 1435×1435 3450×2200×3200
HJSSP-6300/35 6300 35 225-200-150 6 steps Yd11 11100 6200 22000 1435×1435 3750×2400×3750
HJSSP-6300/35 6300 35 215-155 5 steps Yd11 9500 7000 19000 1435×1435 3700×2300×4500
HJSSP-6300/35 6300 35 240-190-160 6 steps Yd11 10800 6150 22000 1435×1435 3990×4160×3920
HJSSPZ-7000/10 7000 10 200-135 7 steps Yd11 12300 6300 21500 1435×1435 4120×2200×3000
HJSSP-7000/10 7000 10 216-161 5 steps Dd0 9800 4650 17500 1435×1435 3600×2200×3600
HJSSP-7000/35 7000 35 220-145 6 steps Yd11 10200 7000 21600 1435×1435 4350×2400×4500
HJSSPZ-7000/35 7000 35 225-188-151 6 steps Yd11 11500 6100 22000 1435×1435 3590×2410×3680
HJSSPZ-7000/35 7000 35 250-204-130 6 steps Yd11 13200 7300 27000 1435×1435 3855×2800×3980
HJSSP-8000/35 8000 35 240-155 6 steps Yd11 10800 7200 22000 1435×1435 4200×2600×4600
HJSSPZ-8000/35 8000 35 270-250-170 9 Yd11 14500 9200 29500 1435×1435 4600×2400×4000
HJSSPZ-8500/35 8500 35 240-220-155 6 Yd11 14000 8500 27500 1435×1435 4500×2500×3700
HJSSP-9000/35 9000 35 240-223-165 13 steps Yd11 10300 6500 21500 1435×1435 4120×2450×4100
HJSSPZ-9000/35 9000 35 240-224-195 9 steps Yd11 12500 8500 27500 1435×1435 4400×2500×4100
HJSSP-10000/10 10000 10 240-170 9 steps Dd0 9800 6000 21000 1435×1435 3800×2420×3900
HJSSPZ-10000/35 10000 35 260-240-160 9 steps Yd11 13500 8800 28000 1435×1435 4400×2500×4400
HJSSPZ-12000/35 12000 35 270-250-165 9 steps Yd11 15200 9600 31500 1435×1435 4500×2600×4300
HJSSP-12000/35 12000 35 270-250-170 9 steps Yd11 15300 8500 31000 1435×1435 4600×2400×4300
HJSSPZ-12500/10 12500 10 270-225-150 15 steps Dd0 12500 9500 27500 1435×1435 4520×2800×4700
HJSSPZ-12500/35 12500 35 270-250-170 9 steps Yd11 15300 9700 31700 1435×1435 4500×2600×4400
HJSSPZ-12500/35 12500 35 270-250-170 9 steps Yd11 16500 8200 29000 1435×1435 3900×2400×3850
HJSSPZ-13000/35 13000 35 240-220-120 9 steps Yd11 19500 9800 36000 1435×1435 4100×3000×4050
HJSSPZ-14000/35 14000 35 290-260-210 9 steps Yd11 16400 9600 31900 1435×1435 4520×3200×4700
HJSSPZ-14000/35 14000 35 300-267-190 11 steps Yd11 20300 10600 41200 1435×1435 4000×3300×4200
HJSSPZ-15000/35 15000 35 370-270-170 13 steps Yd11 27200 12500 49500 1435×1435 4200×4100×4500
HJSSPZ-15000/35 15000 35 300-240-150 11 steps Yd11 17800 10400 37500 1435×1435 4300×3350×4800
HJSSPZ-15000/35 15000 35 315-285-165 13 steps Yd11 18200 10500 35400 1435×1435 4700×2600×4700
HJSSPZ-17000/35 17000 35 330-270-170 9 steps Yd11 25200 13500 48500 1435×1435 4600×3300×4200
HJSSPZ-18000/35 18000 35 345-312-235 11 steps Yd11 20800 12300 42700 1435×1435 4300×3520×5000
HJSSPZ-20000/35 20000 35 350-309-228 13 steps Yd11 21000 12000 39500 1435×1435 4800×2700×4700
HJSSPZ-21000/35 21000 35 340-310-240 11 steps Yd11 24000 12600 43500 1435×1435 5200×3100×4500
HJSSPZ-22000/35 22000 35 370-319-200 11 steps Yd11 27000 12900 48500 1435×1435 4700×3300×4500
HJSSPZ-23000/35 23000 35 350-315-191 13 steps Yd11 26500 13200 47850 1435×1435 4600×3200×4600
HJSSPZ-24000/35 24000 35 395-345-190 17 steps Yd11 26000 11000 43800 1435×1435 4900×2800×4800
HJSSPZ-25000/35 25000 35 400-325-160 17 steps Yd11 26100 15000 51400 1435×1435 4700×4200×5000
HJSSPZ-26000/35 26000 35 400-360-220 17 steps Yd11 26200 15090 52000 1435×1435 4750×3920×5150
HJSSPZ-26000/35 26000 35 420-384-276 13 steps Yd11 29500 14200 55000 1435×1435 4400×3200×5100
HJSSPZ-28000/35 28000 35 420-340-260 19 steps Yd11 27500 16500 56000 1435×1435 5200×3100×5250
HJSSPZ-28000/35 28000 35 425-395-305 13 steps Yd11 31200 15800 5700 1435×1435 4300×3500×5150
HJSSPZ-30000/35 30000 35 480-400-240 19 steps Yd11 31500 18000 65000 2000×2000 4850×3700×5600
HJSSPZ-35000/35 35000 35 380-355-230 13 steps Yd11 39200 18500 71000 2000×2000 4600×3700×5200
HJSSPZ-38000/35 38000 35 480-405-300 19 steps Yd11 35500 20500 74500 2000×2000 5100×5350×5700
HJSSPZ-44000/35 44000 35 486-464-366 19 steps Yd11 36500 22000 78000 2000×2000 6450×4650×5500

* Values are reference data; project guarantees are confirmed in the technical agreement.

Packing & Delivering

Multi-layer protection and expert logistics for safe global transit.

Vacuum Packing
Vacuum Foil Packaging
Wooden Case
Solid Wood Export Cases
Global Routes
Worldwide Delivery

FAQ's

Q: What Determines The Correct Model?

A: The process duty and electrical specification, rather than the product name alone.

Q: Are All Catalogue Values Guaranteed For A New Project?

A: The selected configuration and guaranteed values must be agreed in the technical specification.

Q: What Should I Send For A Quotation? (Ladle Furnace Transformer)

A: Furnace type; capacity; input/output voltage; duty cycle; tap control; cooling.


Inquiry Form

No file chosen
Supported formats: PDF (max 10MB)
  
Thank you. Your inquiry has been received. We will respond within 24 hours.