Aluminium Foil Formation Rectifier Transformer
Overview
The design is selected for the electrical requirements of an aluminium foil formation line. Voltage adjustment and rectifier coordination are key parts of the specification. A rectifier transformer interfaces the incoming AC supply with a rectifier system. Its winding arrangement and electrical ratings must be coordinated with the converter and the downstream process. The source catalogue includes applications in electrochemistry, electrolysis, silicon carbide and graphite furnaces, aluminium foil formation, drives, excitation and medium-frequency furnace power systems. These application groups have distinct requirements and should not share a single generic parameter table. Selection should identify the rectifier topology, pulse arrangement, AC input, valve-side requirements and expected operating cycle. Where a phase-shifting arrangement is required, it must be defined with the converter supplier. Cooling, terminal layout and protection interfaces are also part of the technical review. Provide the converter specification and required DC operating conditions when requesting a quotation. Final winding connections, electrical ratings and accessories are established for the agreed system design. Catalogue models are useful references, but their suitability must be checked against the actual rectifier equipment and load.
Features and Benefits
- Winding configuration can be coordinated with the converter.
- Application-specific tables distinguish different process duties.
Technical Specifications
| Model number |
Rated capacity (kVA) |
Rated voltage | Connection symbol |
Product weight (kg) |
Track gauge (mm) |
Overall dimensions (L × W × H), mm | |||
|---|---|---|---|---|---|---|---|---|---|
|
Primary voltage (kV) |
Secondary (V) |
Body weight | Oil weight | Gross weight | |||||
| ZSZ-265/6.6 | 265 | 6.6 | Customer defined | D.Y1.do.do.Y1 | 1000 | 570 | 2050 | 820×820 | 2150×1250×1800 |
| ZSZ-340/6.6 | 340 | 6.6 | 1200 | 710 | 2500 | 820×820 | 2250×1300×1900 | ||
| ZSZ-380/6.6 | 380 | 6.6 | 1250 | 720 | 2600 | 820×820 | 2300×1380×1900 | ||
| ZSZ-420/6.6 | 420 | 6.6 | 1250 | 750 | 2680 | 820×820 | 2300×1560×1900 | ||
| ZSZ-450/6.6 | 450 | 6.6 | 1400 | 800 | 2850 | 820×820 | 2300×1450×1950 | ||
| ZSZ-490/6.6 | 490 | 6.6 | 1450 | 820 | 2950 | 820×820 | 2300×1560×1950 | ||
| ZSZ-625/6.6 | 625 | 6.6 | 1650 | 850 | 3200 | 820×820 | 2300×1600×2000 | ||
| ZSZ-680/6.6 | 680 | 6.6 | 1680 | 900 | 3300 | 820×820 | 2350×1650×2000 | ||
| ZSZ-720/6.6 | 720 | 6.6 | 1700 | 950 | 3400 | 820×820 | 2350×1700×2000 | ||
| ZSZ-780/6.6 | 780 | 6.6 | 1800 | 960 | 3600 | 820×820 | 2350×1700×2150 | ||
| ZSZ-820/6.6 | 820 | 6.6 | 1850 | 980 | 3700 | 820×820 | 2350×1800×2100 | ||
| ZSZ-860/10 | 860 | 10 | 1880 | 1260 | 4080 | 1070×1070 | 2400×1860×2340 | ||
| ZSZ-1000/10 | 1000 | 10 | 2100 | 1310 | 4560 | 1070×1070 | 2550×2000×2500 | ||
| ZSZ-1240/10 | 1240 | 10 | 2270 | 1500 | 5120 | 1070×1070 | 2430×1870×2590 | ||
| ZSZ-1360/10 | 1360 | 10 | 2230 | 1380 | 4980 | 1070×1070 | 2350×1860×2540 | ||
| ZSZ-1370/10 | 1370 | 10 | 2430 | 1390 | 5010 | 1070×1070 | 2350×1760×2640 | ||
| ZSZ-1500/10 | 1500 | 10 | 2550 | 1500 | 5400 | 1070×1070 | 2450×1900×2600 | ||
| ZSZ-1670/10 | 1670 | 10 | 2780 | 1700 | 5900 | 1070×1070 | 2580×2000×2650 | ||
| ZSZ-2000/10 | 2000 | 10 | 3450 | 2100 | 7300 | 1070×1070 | 3200×2480×3300 | ||
| ZSZ-1250/10 | 1250 | 10 | 2950 | 1500 | 6100 | 1070×1070 | 2600×1800×2650 | ||
| ZSZ-1400/10 | 1400 | 10 | 2950 | 1600 | 6250 | 1070×1070 | 2650×1800×2500 | ||
| ZSZ-1500/35 | 1500 | 35 | 3580 | 2100 | 7650 | 1070×1070 | 2970×2050×2650 | ||
| ZSZ-1590/35 | 1590 | 35 | 3600 | 2150 | 7800 | 1070×1070 | 2970×2100×2650 | ||
| ZSZ-1635/10 | 1635 | 10 | 3400 | 1700 | 3800 | 1070×1070 | 2750×1850×2600 | ||
| ZSZ-1740/35 | 1740 | 35 | 3650 | 2200 | 7900 | 1070×1070 | 2980×2100×2650 | ||
| ZSZ-1820/35 | 1820 | 35 | 4000 | 2500 | 8600 | 1070×1070 | 3170×2190×2700 | ||
| ZSZ-1930/10 | 1930 | 10 | 3500 | 1800 | 7000 | 1070×1070 | 2780×2000×2650 | ||
| ZSZ-1980/35 | 1980 | 35 | 4060 | 2600 | 8900 | 1070×1070 | 3170×2290×2700 | ||
| ZSZ-2020/10 | 2020 | 10 | 3550 | 1850 | 7200 | 1070×1070 | 2750×2050×2650 | ||
| ZSZ-2070/35 | 2070 | 35 | 3920 | 2150 | 8100 | 1070×1070 | 3000×2100×2650 | ||
| ZSZ-2100/35 | 2100 | 35 | 3950 | 2150 | 8150 | 1070×1070 | 3000×2200×2650 | ||
| ZSZ-2150/35 | 2150 | 35 | 4200 | 2200 | 8600 | 1070×1070 | 3050×2250×2750 | ||
| ZSZ-2210/10 | 2210 | 10 | 4150 | 1800 | 8000 | 1070×1070 | 2800×2150×2700 | ||
| ZSZ-2215/35 | 2215 | 35 | 4250 | 1950 | 8500 | 1070×1070 | 3080×2250×2750 | ||
| ZSZ-2300/10 | 2300 | 10 | 4100 | 1900 | 7900 | 1070×1070 | 2780×2200×2700 | ||
| ZSZ-2300/10 | 2300 | 10 | 3950 | 1950 | 7850 | 1070×1070 | 2750×2150×2700 | ||
| ZSZ-2300/10 | 2300 | 10 | 3600 | 1890 | 7600 | 1070×1070 | 2750×2150×2700 | ||
| ZSZ-2300/35 | 2300 | 35 | 4250 | 2250 | 8700 | 1070×1070 | 3100×2250×2750 | ||
| ZSZ-2380/35 | 2380 | 35 | 4350 | 2300 | 9000 | 1070×1070 | 3050×2250×2800 | ||
| ZSZ-2430/35 | 2430 | 35 | 4420 | 2380 | 9300 | 1070×1070 | 3050×2280×2800 | ||
| ZSZ-2450/10 | 2450 | 10 | 4100 | 2000 | 8100 | 1070×1070 | 2800×2300×2750 | ||
| ZSZ-2490/35 | 2490 | 35 | 4600 | 2300 | 9350 | 1070×1070 | 3050×2350×2800 | ||
| ZSZ-2540/10 | 2540 | 10 | 4400 | 1900 | 8450 | 1070×1070 | 2820×2300×2750 | ||
| ZSZ-2580/10 | 2580 | 10 | 4450 | 1960 | 8500 | 1070×1070 | 2850×2300×2750 | ||
| ZSZ-2600/35 | 2600 | 35 | 4500 | 2330 | 9500 | 1070×1070 | 3050×2350×2800 | ||
| ZSZ-2670/10 | 2670 | 10 | 4450 | 1960 | 8650 | 1070×1070 | 3050×2350×2750 | ||
| ZSZ-2735/35 | 2735 | 35 | 4600 | 2380 | 9600 | 1070×1070 | 3050×2250×2850 | ||
| ZSZ-2780/10 | 2780 | 10 | 4900 | 2000 | 9200 | 1070×1070 | 2900×2300×2850 | ||
| ZSZ-2830/10 | 2830 | 10 | 4950 | 2100 | 9300 | 1070×1070 | 2900×2350×2850 | ||
| ZSZ-2930/35 | 2930 | 35 | 4600 | 2450 | 9700 | 1070×1070 | 3050×2450×2850 | ||
| ZSZ-2960/35 | 2960 | 35 | 5500 | 2500 | 10200 | 1070×1070 | 3070×2300×2900 | ||
| ZSZ-3170/35 | 3170 | 35 | 5560 | 2550 | 10600 | 1070×1070 | 3080×2450×2900 | ||
* Values are reference data; project guarantees are confirmed in the technical agreement.
Packing & Delivering
Multi-layer protection and expert logistics for safe global transit.
FAQ's
Q: What Determines The Correct Model?
A: The process duty and electrical specification, rather than the product name alone.
Q: Are All Catalogue Values Guaranteed For A New Project?
A: The selected configuration and guaranteed values must be agreed in the technical specification.
Q: What Should I Send For A Quotation?
A: Rectifier topology; pulses; AC input; valve-side voltage; DC output duty; cooling.