Power & Distribution Transformers

35 kV Oil-Immersed Power Transformer

35 kV Oil-Immersed Power Transformer
35 kV Oil-Immersed Power Transformer

Overview

A 35 kV oil-immersed power transformer is selected for power conversion at the specified system voltage level. The reference catalogue provides configurations with rated capacity, winding voltages, tapping ranges, vector groups and impedance values. On-load and off-circuit tap-changing arrangements are listed separately and must be selected to suit the operating requirement. The design review should establish the required number of windings, network voltages, load profile and installation environment. Rated voltage alone is not enough to define a complete transformer specification. Buyers should also provide the frequency, required losses, insulation requirements, cooling arrangement and applicable project specification. Accessories, terminal arrangements and protection interfaces are agreed with the installation designer. For replacement projects, include the existing nameplate and foundation drawing. The catalogue tables supplied with this material package are reference data from the existing product documents. Final guaranteed values, test scope and overall dimensions must be confirmed in the project technical agreement and approved drawing before manufacture.

Request a Quote

Features and Benefits

  • Separate tap-changing configurations support different operating requirements.
  • Project-specific electrical and mechanical review supports installation coordination.

Technical Specifications

35kV oil-immersed three-phase double-winding off-circuit tap changing power transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Impedance voltage
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
LV
3150 35~38.5 ±2×2.5 3.15 Yd11 0.36 7.0 1.7 20.7
4000 6.3 2.0 24.6
5000 ±5 10.5 2.4 28.2
6300   2.9 31.5
8000 ±2×2.5   YNd11 0.28 8.0 4.0 34.6
10000 3.15 4.8 40.8
12500 3.3 0.24 5.5 48.4
16000 6.3 6.7 59.2
20000 6.6 7.9 71.6
25000 10.5 0.20 10.0 9.4 84.6
31500   11.1 100.8

* Values are reference data; project guarantees are confirmed in the technical agreement.


35kV oil-immersed three-phase double-winding on-load regulating power transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Impedance voltage
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
LV
3150 35~38.5 ±3×2.5 6.3 Yd11 0.40 7.0 1.8 22.2
4000 35~38.5 ±3×2.5 6.3 Yd11 0.40 7.0 2.1 26.2
5000 35~38.5 ±3×2.5 10.5 Yd11 0.40 7.0 2.6 30.8
6300 35~38.5 ±3×2.5 10.5 Yd11 0.40 7.0 3.1 33.0
8000 35~38.5 ±3×2.5 6.3 YNd11 0.32 7.5 or 8.0 4.3 36.5
10000 35~38.5 ±3×2.5 6.3 YNd11 0.32 7.5 or 8.0 5.1 43.2
12500 35~38.5 ±3×2.5 6.3 YNd11 0.28 7.5 or 8.0 6.0 51.1
16000 35~38.5 ±3×2.5 6.6 YNd11 0.28 7.5 or 8.0 7.2 63.3
20000 35~38.5 ±3×2.5 10.5 YNd11 0.28 10.0 8.5 74.4
25000 35~38.5 ±3×2.5 10.5 YNd11 0.24 10.0 10.1 88.0
31500 35~38.5 ±3×2.5 10.5 YNd11 0.24 10.0 12.0 104.4

* Values are reference data; project guarantees are confirmed in the technical agreement.

Packing & Delivering

Multi-layer protection and expert logistics for safe global transit.

Vacuum Packing
Vacuum Foil Packaging
Wooden Case
Solid Wood Export Cases
Global Routes
Worldwide Delivery

FAQ's

Q: How Are Price And Lead Time Confirmed?

A: They are confirmed after reviewing the specification and quantity.

Q: Can Voltage Level Alone Determine A Model?

A: No. Capacity, winding arrangement, impedance, taps and site conditions are also required.

Q: What Information Is Needed For A Quotation? (Oil-Immersed Power Transformer)

A: Capacity; winding voltages; winding count; vector group; impedance; taps; losses; cooling.