110 kV Oil-Immersed Power Transformer

110 kV Oil-Immersed Power Transformer
110 kV Oil-Immersed Power Transformer

Overview

A 110 kV oil-immersed power transformer is selected for power conversion at the specified system voltage level. The reference catalogue provides configurations with rated capacity, winding voltages, tapping ranges, vector groups and impedance values. On-load and off-circuit tap-changing arrangements are listed separately and must be selected to suit the operating requirement. The design review should establish the required number of windings, network voltages, load profile and installation environment. Rated voltage alone is not enough to define a complete transformer specification. Buyers should also provide the frequency, required losses, insulation requirements, cooling arrangement and applicable project specification. Accessories, terminal arrangements and protection interfaces are agreed with the installation designer. For replacement projects, include the existing nameplate and foundation drawing. The catalogue tables supplied with this material package are reference data from the existing product documents. Final guaranteed values, test scope and overall dimensions must be confirmed in the project technical agreement and approved drawing before manufacture.

Request a Quote

Features and Benefits

  • Separate tap-changing configurations support different operating requirements.
  • Project-specific electrical and mechanical review supports installation coordination.

Technical Specifications

110kV oil-immersed three-phase double-winding off-circuit tap changing power transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Impedance voltage
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
LV
6300 110
115
121
±2×2.5 6.3
6.6
10.5
YNd11 0.5 10.5 4.1 32
8000 0.5 4.9 38
10000 0.46 5.8 45
12500 0.46 6.8 53
16000 0.43 8.3 65.7
20000 0.43 9.7 79
25000 0.4 11.4 94
31500 0.36 13.5 111
40000 0.36 16.2 133
50000 0.34 19.4 158
63000 0.3 22.9 187
75000 13.8
15.75
18
21
0.26 12-14 26.0 212
90000 0.24 29.9 245
120000 0.22 37.3 303
150000 0.19 44.1 359
180000 0.16 49.5 411

* Values are reference data; project guarantees are confirmed in the technical agreement.


110kV oil-immersed three-phase three-winding off-circuit tap changing transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Short-circuit impedance
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
MV LV Step-up Step-down
6300 110
115
121
±2×2.5 36
37
38.5
6.3
6.6
10.5
21
YNyn0d11 0.53 HV-MV: 17.5-18.5
HV-LV: 10.5
MV-LV: 6.5
HV-MV: 10.5
HV-LV: 17.5-19
MV-LV: 6.5
4.9 40
8000 0.5 5.8 48
10000 0.47 6.9 56
12500 0.45 8.1 67
16000 0.42 9.8 81
20000 0.42 11.6 95
25000 0.38 13.5 113
31500 0.38 16.2 134
40000 0.35 19.1 161
50000 0.35 22.9 192
63000 0.32 27.1 230

* Values are reference data; project guarantees are confirmed in the technical agreement.


110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Impedance voltage
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
LV
6300 110 ±4×1.25
±6×1.25
±8×1.25
6.3
6.6
10.5
21
YNd11 0.51 10.5 4.4 32
8000 0.51 5.3 38
10000 0.47 6.2 45
12500 0.47 7.4 53
16000 0.44 8.9 66
20000 0.44 10.6 79
25000 0.41 12.5 94
31500 0.41 14.9 111
40000 0.37 10.5-18 17.8 140
50000 0.37 21.0 175
63000 0.34 25.0 209

* Values are reference data; project guarantees are confirmed in the technical agreement.


110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer

Rated capacity
(kVA)
Rated voltage and tapping range Vector group No load current
(%)
Impedance voltage
(%)
No load losses
(kW)
On load losses
(kW)
HV Tapping range
(%)
MV LV
6300 110 ±4×2.5
±6×2.5
±8×2.5
36
37
38.5
6.3
6.6
10.5
21
YNyn0d11 0.61 HV-MV: 10.5
HV-LV: 17.5-19
MV-LV: 6.5
5.3 40
8000 0.61 6.3 48
10000 0.57 7.5 56
12500 0.57 8.9 67
16000 0.54 10.6 81
20000 0.54 12.5 95
25000 0.5 14.9 113
31500 0.5 17.7 134
40000 0.46 21.2 161
50000 0.46 25.0 192
63000 0.42 29.8 230

* Values are reference data; project guarantees are confirmed in the technical agreement.

Packing & Delivering

Multi-layer protection and expert logistics for safe global transit.

Vacuum Packing
Vacuum Foil Packaging
Wooden Case
Solid Wood Export Cases
Global Routes
Worldwide Delivery

FAQ's

Q: How Are Price And Lead Time Confirmed?

A: They are confirmed after reviewing the specification and quantity.

Q: What Information Is Needed For A Quotation? (Oil-Immersed Distribution Transformer)

A: Capacity; primary/secondary voltage; frequency; loss requirements; taps; site.

Q: Can Voltage Level Alone Determine A Model?

A: No. Capacity, winding arrangement, impedance, taps and site conditions are also required.


Inquiry Form

No file chosen
Supported formats: PDF (max 10MB)
  
Thank you. Your inquiry has been received. We will respond within 24 hours.